Article Detail

Home > Article Detail
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Methodological Study on Measurement of Hydrogen Abundance in Hydrogen Isotopes System by Low Resolution Mass Spectrometry

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2011, v.2 no.1, pp.1-7
https://doi.org/10.5478/MSL.2011.2.1.001
Li Jin-ying (China National Nuclear Corporation)
Shi Lei (China Institute of Atomic Energy)
Hu Shi-lin (China Institute of Atomic Energy)
  • Downloaded
  • Viewed

Abstract

China’s rapid economic growth has resulted in significant environmental side-effects. Therefore, China has beeninterested in reducing her dependence on foreign oil and gas by developing technologies needed for hydrogen, in addition to herincreasing energy mix of nuclear and renewable energy form such as solar and wind power. There are three isotopes of hydrogen,i.e. protium (P or H), deuterium (D), and tritium (T). Both deuterium and tritium are important materials in nuclear fuel cycleindustry. Tritium is one of the critical radioactive nuclides. Planning for and implementing contamination control as a part ofnormal operation and maintenance activities is an important function in any hydrogen facility, especially tritium facility. Thedevelopment of hydrogen isotopes analysis is the key issues in this area. Mass spectrometry (MS) with medium (about 600) andhigh resolution (>1400) is commercially available; however, the routine analysis of hydrogen isotopes is done with low-resolutionMS (<200) in China. This paper summarizes the progress of MS measurement technology for hydrogen isotope abundance inChina, focusing on our lab’s research program and technical status. An analyzing method has been introduced for accurate measurementof tritium abundance in the H-D-T system by low resolution MAT-253 MS. The quotient of compression ratio coefficient isdetermined based on building up equipment for laboratory-scale preparation of secondary standard gases and considering thedifference in sensitivity between hydrogen isotopes. The results show that the measured value is believable in the relative errorrange of 0.8% for gas samples of different tritium abundance.

keywords
Hydrogen Isotopes, Tritium Abundance, Low Resolution Mass Spectrometry, Compression Ratio Coefficient


Reference

1

Nuclear Scientific and Technolgical Information Institute. (2000). Manual Book of Nuclear Energy:Atomic Energy Press.

2

Lawrence Berkely laboratory. (1972). Instrumentation for Environmental Monitoring. .

3

Pollay, M. Solubilization of animal tissues for liquid scintillation counting.

4

Xu, Z. (2003). Disposal of radioactive Waste of Tritium:China Atomic Energy Press.

5

Mohammad, A. K. (2003). . The Arabian Journal for Science and Engineering, 28(2A), 147-.

6

Chen, G. Spectroscopy and Spectral Analysis.

7

Fukuda, S. (1995). . J. Nucl. Mater, , 226-.

8

Fukuda, S. (1999). . Sep. Sci. Tech, 34, 2234-.

9

Luo, S.. (2003). An outline of radioactive waste [M]:Atomic Energy Press.

10

Nuclear Scientific and Technolgical Information Institute. (2000). Manual Book of Nuclear Energy:Atomic Energy Press.

11

Liu, Q. (1985). . Journal of Chinese Mass Spectrometry Society, , -.

12

Shi, L.. (2008). . Journal of Chinese Mass Spectrometry Society, 29(Suppl), 52-.

13

Shi, L. (2009). . Journal of Nuclear and Radiochemistry, 31, 148-.

14

Shi, L. (2009). Analysis of hydrogen isotopes By GC, MS And GC-MS (-). Corpus of the Fourth National Environmental Nuclear and Radiochemistry Conference.

15

Huanu, G. (2006). . Journal of Chinese Mass Spectrometry Society, 27(Supple), 37-.

16

Zhang, H. (2001). . Journal of Chinese Mass Spectrometry Society, 22, 25-.

17

Shi, L. (2009). Gas preparation of hydrogen isotopes and a gas preparation method of deuterium and tritium (-). Annual Conference on CNC.

18

Shi, L. (2009). Ratios of monatomic ions computation problem of hydrogen isotope abundance with low-resolution MS (-). Annual Conference on Mass Spectrometry.

19

Zhang, H.-L. (2003). Atomic Energy Science and Technology:China Atomic Energy Press.

Submission Date
2010-12-02
Revised Date
2010-12-09
Accepted Date
2010-12-09
상단으로 이동

Mass Spectrometry Letters