Article Detail

Home > Article Detail
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Accurate Measurement of Isotope Amount Ratios of Lead in Bronze with Multicollector Inductively Coupled Plasma Mass Spectrometry

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2013, v.4 no.4, pp.87-90
https://doi.org/10.5478/MSL.2013.4.4.87
Lee Kyoung-Seok (Korea Research Institute of Standard and Science)
Kim Jin-il (Korea Research Institute of Standard and Science)
Yim Yong-Hyeon (Korea Research Institute of Standard and Science)
Hwang Euijin (Korea Research Institute of Standard and Science)
Kim Tae Kyu (Pusan National University)
  • Downloaded
  • Viewed

Abstract

Isotope amount ratios of lead in a bronze sample have been successfully determined using multicollector inductivelycoupled plasma mass spectrometry (MC-ICP-MS). Matrix separation conditions were tested and optimized using ion exchangechromatography with anion-exchange resin, AG1-X8, and sequential elution of the 0.5 M HBr and 7 M HNO3 to separate leadfrom very high contents of copper and tin in bronze matrix. Mercury was also removed efficiently in the optimized separationcondition. The instrumental isotope fractionation of lead in the MC-ICP-MS measurement was corrected by the external standardsample bracketing method using an external standard, NIST SRM 981 lead common isotope ratio standard followed by correctionof procedure blank to obtain reliable isotope ratios of lead. The isotope ratios, 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb, and208Pb/206Pb, of lead were determined as 18.0802 ± 0.0114, 15.5799 ± 0.0099, 38.0853 ± 0.0241, and 2.1065 ± 0.0004, respectively,and the determined isotope ratios showed good agreement with the reference values of an international comparison for thesame sample within the stated uncertainties.

keywords
isotope ratio, lead, MC-ICP-MS, bronze, matrix separation


Reference

1

Cohen, E. R. (2008). Quantities, Units and Symbols in Physical Chemistry, IUPAC Green Book:IUPAC & RSC Publishing.

2

Vanhaecke, F. (2012). Isotopic Analysis: Fundamentals and Applications Using ICP-MS:Wiley- VCH Verlag & Co. KGaA.

3

Balcaen, L. (2010). . Spectrochim. Acta, Part B, 65, 769-.

4

Cheng, H. (2010). . Environmental Pollution, 158, 1134-.

5

Díaz-Somoano, M. (2009). . Environ. Sci. Technol, 43, 1078-.

6

Heumann, K. G. (1998). . J. Anal. At. Spectrom, 13, 1001-.

7

Albarède, F. (2004). . Reviews in Mineralogy & Geochemistry, 55, 113-.

8

Yang, L. (2009). . Mass Spectrom. Rev, 28, 990-.

9

Weyer, S. (2003). . Int. J. Mass Spectrom, 226, 355-.

10

Andersen, T. (1962). . Acta Chemica Scandinavica, 16, 849-.

11

Strelow, F. W. E. (1966). . Anal. Chem, 38, 545-.

12

Guide to the Expression of Uncertainty in Measurement.

Submission Date
2013-12-13
Revised Date
2013-12-19
Accepted Date
2013-12-19