Article Detail

Home > Article Detail
  • P-ISSN 2233-4203
  • E-ISSN 2093-8950

Complete Simultaneous Analysis of Uranium Isotopes in NUSIMEP-7 Microparticles Using SEM-TIMS

Mass Spectrometry Letters / Mass Spectrometry Letters, (P)2233-4203; (E)2093-8950
2016, v.7 no.3, pp.64-68
https://doi.org/10.5478/MSL.2016.7.3.64
Park Jong-Ho (Korea Atomic Energy Research Institute, University of Science and Technology)
Jeong Kahee (Korea Atomic Energy Research Institute)
  • Downloaded
  • Viewed

Abstract

Scanning electron microscopy combined with thermal ionization mass spectrometry (SEM-TIMS) was used to determine the precise isotope ratios of ultra-trace levels of uranium contained in individual microparticles. An advanced multiple ion counter system consisting of three secondary ion multipliers and two compact discrete dynodes was used for complete simultaneous ion detection. For verification purposes, using TIMS with complete simultaneous measurement, isotopes were analyzed in 5 pg of uranium of a certified reference material. A microprobe in the SEM was used to transfer individual particles from a NUSIMEP-7 sample to TIMS filaments, which were then subjected to SEM-TIMS and complete simultaneous measurement. The excellent agreement in the resulting uranium isotope ratios with the certified NUSIMEP-7 values shows the validity of SEM-TIMS with complete simultaneous measurement for the analysis of uranium isotopes in individual particles. Further experimental study required for investigation of simultaneous measurement using the advanced multiple ion counter system is presented.

keywords
Thermal Ionization Mass Spectrometry, Uranium, SEM-TIMS, Particle analysis, Simultaneous measurement


Reference

1

Donohue, D. L.. (1998). . J. Alloy Compd, 271-273, 11-.

2

Donohue, D. L.. (2008). . Appl. Surf. Sci, 255, 2561-.

3

Magara, M.. (2000). . Appl. Radiat. Isotopes, 53, 87-.

4

Farmer III, O. T.. (2008). . J. Radional. Nucl. Chem, 276, 489-.

5

Park, J.-H.. (2015). . J. Radioanal. Nucl. Chem, 303, 1297-.

6

Heumann, K. G.. (1995). . Analyst, 120, 1291-.

7

Stetzer, O.. (2004). . Nucl. Instr. Meth. Phys. Res. A, 525, 582-.

8

Lee, C. G.. (2006). . Nucl. Inst. Meth. Phys. Res. B, 245, 440-.

9

Kraiem, M.. (2011). . Anal. Chem, 83, 3011-.

10

박종호. (2013). Isotopic Analysis of NUSIMEP-6 Uranium Particles using SEM-TIMS. Mass Spectrometry Letters, 4(3), 51-54. http://dx.doi.org/10.5478/MSL.2013.4.3.51.

11

Truyens, J.. (2013). . J. Environ. Radioact, 125, 50-.

12

Jong Ho Park. (2010). A Technique to Minimize Impurity Signal from Blank Rhenium Filaments for Highly Accurate TIMS Measurements of Uranium in Ultra-Trace Levels. Mass Spectrometry Letters, 1(1), 17-20. http://dx.doi.org/10.5478/MSL.2010.1.1.017.

13

Suzuki, D.. (2010). . Int. J. Mass Spectrom, 294, 23-.

14

박종호. (2011). A Correction Method for the Peak Tailing Backgrounds for Accurate Isotope Ratio Measurements of Uranium in Ultra Trace Levels using Thermal Ionization Mass Spectrometry. Bulletin of the Korean Chemical Society, 32(12), 4327-4331.

15

Park, J. -H.. (2013). . Asian J. Chem, 25, 7061-.

16

Guide to the expression of uncertainty in measurement.

17

Bürger, S.. (2010). . Int. J. Mass Spectrom, 294, 65-.

18

Richter, S.. (2003). . Int. J. Mass Spectrom, 229, 181-.

19

Qualification procedure for the network of analytical laboratories for environmental sampling, SG-SGAS-9006.

Submission Date
2016-07-27
Revised Date
2016-08-28
Accepted Date
2016-08-28
상단으로 이동

Mass Spectrometry Letters